Seriozitatea, responsabilitatea şi orientarea spre performanţă sunt direcţiile noastre de acţiune în prezent şi în viitor.

Main

Range of product

Zelio Logic

Product or component type

Compact smart relay

Local display

With

[Us] rated supply voltage

24 V DC

Supply current

100 mA without extension

Discrete input number

8 EN/IEC 61131-2 type 1

Discrete input current

4 mA

Analogue input number

4

Number of outputs

4 relay

Clock

With



Complementary

Number or control scheme lines

120 ladder
≤ 200 FBD

Cycle time

6...90 ms

Backup time

10 years 25 °C

Clock drift

6 s/month 25 °C
12 min/year 0...55 °C

Checks

Program memory on each power up

Supply voltage limits

19,2...30 V

Power dissipation in W

3 W without extension

Reverse polarity protection

With

Discrete input type

Resistive

Discrete input voltage

24 V DC

Counting frequency

1 kHz discrete input

Voltage state1 guaranteed

≥ 15 V IB...IG used as discrete input circuit
≥ 15 V I1...IA and IH...IR discrete input circuit

Voltage state 0 guaranteed

≤ 5 V IB...IG used as discrete input circuit
≤ 5 V I1...IA and IH...IR discrete input circuit

Current state 1 guaranteed

≥ 1,2 mA IB...IG used as discrete input circuit
≥ 2,2 mA I1...IA and IH...IR discrete input circuit

Current state 0 guaranteed

< 0,5 mA IB...IG used as discrete input circuit
< 0,75 mA I1...IA and IH...IR discrete input circuit

Input compatibility

3-wire proximity sensors PNP discrete input

Analogue input type

Common mode

Analogue input range

0...10 V
0...24 V

Maximum permissible voltage

30 V analogue input circuit

Analogue input resolution

8 bits

LSB value

39 mV analogue input circuit

Conversion time

Smart relay cycle time analogue input circuit

Conversion error

+/- 5 % 25 °C analogue input circuit
+/- 6.2 % 55 °C analogue input circuit

Repeat accuracy

+/- 2 % 55 °C analogue input circuit

Operating distance

10 m between stations, with screened cable (sensor not isolated) analogue input circuit

Input impedance

7,4 kOhm I1...IA and IH...IR discrete input circuit
12 kOhm IB...IG used as analogue input circuit
12 kOhm IB...IG used as discrete input circuit

Output voltage limits

5...30 V DC relay output
24...250 V AC relay output

Contacts type and composition

NO relay output

Output thermal current

8 A for all 4 outputs relay output

Electrical durability

500000 cycles DC-12 24 V 1,5 A relay output EN/IEC 60947-5-1
500000 cycles DC-13 24 V 0,6 A relay output EN/IEC 60947-5-1
500000 cycles AC-12 230 V 1,5 A relay output EN/IEC 60947-5-1
500000 cycles AC-15 230 V 0,9 A relay output EN/IEC 60947-5-1

Switching capacity in mA

≥ 10 mA 12 V relay output

Operating rate in Hz

0,1 Hz at Ie relay output
10 Hz no load relay output

Mechanical durability

10000000 cycles relay output

[Uimp] rated impulse withstand voltage

4 kV EN/IEC 60947-1 and EN/IEC 60664-1

Response time

5 ms from state 1 to state 0 relay output
10 ms from state 0 to state 1 relay output

Connections - terminals

Screw terminals 1 x 0.25...1 x 2.5 mm² 24...14 flexible with cable end
Screw terminals 2 x 0.2...2 x 1.5 mm² 24...16 solid
Screw terminals 1 x 0.2...1 x 2.5 mm² 25...14 solid
Screw terminals 1 x 0.2...1 x 2.5 mm² 25...14 semi-solid
Screw terminals 2 x 0.25...2 x 0.75 mm² 24...18 flexible with cable end

Tightening torque

0,5 N.m

Overvoltage category

III EN/IEC 60664-1

Product weight

0,25 kg



Environment

Immunity to microbreaks

≤ 1 ms

Product certifications

C-Tick
CSA
GL
GOST
UL

Standards

EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-11
EN/IEC 61000-4-12
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3

IP degree of protection

IP20 terminal block IEC 60529
IP40 front panel IEC 60529

Environmental characteristic

EMC directive EN/IEC 61131-2 zone B
EMC directive EN/IEC 61000-6-2
EMC directive EN/IEC 61000-6-3
EMC directive EN/IEC 61000-6-4
Low voltage directive EN/IEC 61131-2

Disturbance radiated/conducted

Class B EN 55022-11 group 1

Pollution degree

2 EN/IEC 61131-2

Ambient air temperature for operation

-20...40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
-20...55 °C IEC 60068-2-1 and IEC 60068-2-2

Ambient air temperature for storage

-40...70 °C

Operating altitude

2000 m

Altitude transport

≤ 3048 m

Relative humidity

95 % without condensation or dripping water

RoHS EUR conformity date

0622

RoHS EUR status

Compliant